492 third-party lab reports published Volume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded 99.63% median purity across 282 lots 262 / 262 lots pass sterility

‹ Certificates Semax Lot 1801

Lab report (Certificate of Analysis, COA)

Semax · 10 mg

Batch 1801 · tested October 20, 2026 (29 days ago) · released October 27, 2026

All tests passed

Batch
#1801 14 of 15 tests
Mass
10 mg
Purity
98.95%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01

3 units tested for purity: 98.91 / 99.00 / 98.95% · spread 0.09 pt · net peptide content 10.98 / 11.06 / 10.86 mg

Conformity: Units agree — every reported unit passed on all 11 test rows · purity spread 0.09 pt within the house limit · content spread 1.8% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Director, 2026-10-20

Vanguard · issuing lab

Reports for this lot

  1. Vanguard Laboratory this report · tested October 20, 2026 · 11 results · QA approvalVanguard · issuing labAll tests passed
  2. Ethos Analytics Laboratory tested October 22, 2026 · 3 results · QA approvalEthos Analytics · issuing labAll tests passed

Test by test

11 results on the report · 3 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 5 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓IdentityPass
1 of 1 pass · 1 unit · USP <621> (procedural chapter)
✓PurityWithin limits
avg 98.95% · 3 units · USP <621> (procedural chapter)
✓Purity consistency between unitsWithin house limit
3 units: 98.91 / 99.00 / 98.95% · spread 0.09 pt · house limit · caution past 0.50 pt, outside past 1.00 pt · per-unit USP <621> results
✓Net peptide content (assay)Within limits
avg 10.97 mg · 3 units · USP <621> (procedural chapter)
✓Content consistency between unitsWithin house limit
3 units: 10.98 / 11.06 / 10.86 mg · spread 0.20 mg, 1.8% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
✓Heavy metalsWithin limits
5 elements non-detect · 2 units · dose-scaled limits derived from USP <232> (limits chapter)

✓Residual solventsWithin limits
all non-detect · 1 unit · USP <467> (procedural chapter)
✓Trifluoroacetic acidWithin limits
all non-detect · 1 unit · house limit · ion chromatography, the lab's method; no compendial chapter for the method run · limit <0.10% (the lab's)
✓EndotoxinsPass
3 of 3 pass · 3 units · USP <85> (procedural chapter) · limit <5.00 EU/mg (the lab's)
✓Container closurePass
3 of 3 pass · 3 units · USP <1207> (informational chapter (1000-series))
✓SolubilityPass
3 of 3 pass · 3 units · house check · no compendial chapter
✓SterilityPass
5 of 5 pass · 5 units · USP <71> (procedural chapter)
✓Other · Adulterant screenWithin limits
all non-detect · 1 unit · no chapter named in the record; a screen
✓ConformityUnits agree
every reported unit passed on all 11 test rows · purity spread 0.09 pt within the house limit · content spread 1.8% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Director, 2026-10-20 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Lab reports for batch 1801

First page of the Vanguard Laboratory report · Batch 1801

Vanguard Laboratory report · Batch 1801

Vanguard Laboratory's report for this batch, as the lab issued it.

3 pages · Vanguard report V260930-22 001

Open PDF
Download

First page of the Ethos Analytics report · Batch 1801

Ethos Analytics report · Batch 1801

Ethos Analytics' report for this batch, as the lab issued it.

This PDF is locked by the lab: it opens and prints, but cannot be edited.

Open PDF
Download

Tested by Vanguard Laboratory · Released October 27, 2026 · Verify: go.peptidology.co/BVJW6U

Permanent URL: https://peptidology.co/coa/semax-size-10mg-batch-1801-lot-1801/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 18 times.