492 third-party lab reports publishedVolume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded99.63% median purity across 282 lots262 / 262 lots pass sterility492 third-party lab reports publishedVolume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded99.63% median purity across 282 lots262 / 262 lots pass sterility
No tier shown — see the tests listed on the report
3 units tested for purity, each printed >99% · net peptide content · semax label claim 10.68 / 10.76 / 10.72 mg/vial
Conformity: Units agree — every reported unit passed on all 3 test rows · purity: every unit above the same 99.00% bound, no difference reported · content spread 0.7% within the house limit · QA approval corroborates: Ethos Analytics Laboratory, Noel Samsum, 2026-10-22
3 results on the report · 3 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 3 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows
✓IdentityPass
3 of 3 pass · 3 units · USP <621> (procedural chapter)
✓Purity consistency between unitsWithin house limit
3 units, each above 99.00% (the lab's reporting bound) · every unit printed the same bound, so the report shows no difference between units (the bound allows at most 1.00 pt) · house limit · caution past 0.50 pt, outside past 1.00 pt · per-unit USP <621> results
✓Content consistency between unitsWithin house limit
3 units: 10.68 / 10.76 / 10.72 mg/vial · spread 0.08 mg/vial, 0.7% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓ConformityUnits agree
every reported unit passed on all 3 test rows · purity: every unit above the same 99.00% bound, no difference reported · content spread 0.7% within the house limit · QA approval corroborates: Ethos Analytics Laboratory, Noel Samsum, 2026-10-22 · house check · agreement across all tests, unit to unit; QA approval corroborates
A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.
Ethos Analytics report · Batch 1801
Ethos Analytics' report for this batch, as the lab issued it.
This PDF is locked by the lab: it opens and prints, but cannot be edited.