Lab report (Certificate of Analysis, COA)
PGL-A2 (Amylin-Calcitonin Agonist) · 10 mg
All tests passed
- Batch
- #1793 15 tests
- Mass
- 10 mg
- Purity
- 98.73%
- Issuing lab accreditation
- Vanguard · ISO 17025:2017 / A2LA #6377.01.01
3 units tested for purity: 98.73 / 98.69 / 98.63% · spread 0.10 pt · net peptide content 9.28 / 9.17 / 9.26 mg
Conformity: Units agree — every reported unit passed on all 12 test rows · purity spread 0.10 pt within the house limit · content spread 1.2% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-10-15
Vanguard · issuing labEagle Analytical · sterility
Reports for this lot
- Vanguard Laboratory this report · tested October 15, 2026 · 12 results · QA approvalVanguard · issuing labEagle Analytical · sterilityAll tests passed
- ILS Laboratories tested October 29, 2026 · 5 results · QA approvalILS Laboratories · issuing labAll tests passed
- Ethos Analytics Laboratory tested October 22, 2026 · 3 results · QA approvalEthos Analytics · issuing labAll tests passed
Tested at ILS Laboratories and Ethos Analytics Laboratory
2 approved lab reports for lot 1793. Every unit each lab tested is shown below, lab by lab; the combined line counts measured units only, and a printed threshold stays exactly as the lab printed it. Each report keeps its own verdict.
| ILS Laboratories | Peptide Purity (HPLC): 99.72 · 99.90 · 99.90 · 99.89 | 4 units |
|---|---|---|
| Ethos Analytics Laboratory | Chromatographic Purity: >99 · >99 · >99 | 3 units |
| ILS Laboratories | Net Peptide Content: 10.7 · 10.39 · 10.59 · 10.64 mg | 4 units |
|---|---|---|
| Ethos Analytics Laboratory | Cagrilintide Label Claim: 10.97 · 10.88 · 10.94 mg/vial | 3 units |
| ILS Laboratories | Confirmed · Confirmed · Confirmed · Confirmed | 4 units |
|---|---|---|
| Ethos Analytics Laboratory | Pass · Pass · Pass | 3 units |
| Across labs | Pass at ILS Laboratories, Ethos Analytics Laboratory | |
Test by test
12 results on the report · 3 rows computed from the per-unit values · 2 labs · each test used up to 5 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows
A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.
Lab reports for batch 1793