Lab report (Certificate of Analysis, COA)
PGL-A2 (Amylin-Calcitonin Agonist)
All tests passed
- Batch
- #1793 5 tests
- Purity
- >99%
- Issuing lab accreditation
- Ethos Analytics · ISO/IEC 17025:2017, ISO/IEC 17025 Acc #: 117798, Lic #: 000026LRCND60176649
No tier shown — see the tests listed on the report
3 units tested for purity, each printed >99% · net peptide content · cagrilintide label claim 10.97 / 10.88 / 10.94 mg/vial
Conformity: Units agree — every reported unit passed on all 3 test rows · purity: every unit above the same 99.00% bound, no difference reported · content spread 0.8% within the house limit · QA approval corroborates: Ethos Analytics Laboratory, Noel Samsum, 2026-10-22
Ethos Analytics · issuing lab
Reports for this lot
- ILS Laboratories tested October 29, 2026 · 5 results · QA approvalILS Laboratories · issuing labAll tests passed
- Ethos Analytics Laboratory this report · tested October 22, 2026 · 3 results · QA approvalEthos Analytics · issuing labAll tests passed
Tested at ILS Laboratories and Ethos Analytics Laboratory
2 approved lab reports for lot 1793. Every unit each lab tested is shown below, lab by lab; the combined line counts measured units only, and a printed threshold stays exactly as the lab printed it. Each report keeps its own verdict.
- ILS Laboratories — headline report
- Ethos Analytics Laboratory
| ILS Laboratories | Peptide Purity (HPLC): 99.72 · 99.90 · 99.90 · 99.89 | 4 units |
|---|---|---|
| Ethos Analytics Laboratory | Chromatographic Purity: >99 · >99 · >99 | 3 units |
| ILS Laboratories | Net Peptide Content: 10.7 · 10.39 · 10.59 · 10.64 mg | 4 units |
|---|---|---|
| Ethos Analytics Laboratory | Cagrilintide Label Claim: 10.97 · 10.88 · 10.94 mg/vial | 3 units |
| ILS Laboratories | Confirmed · Confirmed · Confirmed · Confirmed | 4 units |
|---|---|---|
| Ethos Analytics Laboratory | Pass · Pass · Pass | 3 units |
| Across labs | Pass at ILS Laboratories, Ethos Analytics Laboratory | |
Test by test
3 results on the report · 3 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 3 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows
A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.
Lab reports for batch 1793