444 third-party lab reports published3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Monday night. For research use only.99.59% median purity across 251 lotsDefense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified239 / 239 lots pass sterility444 third-party lab reports published3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Monday night. For research use only.99.59% median purity across 251 lotsDefense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified239 / 239 lots pass sterility
Batch 1669 · tested February 4, 2026 (228 days ago) · released May 25, 2026 Discontinued variant
All tests passed
Batch
#1669 9 tests
Mass
500 mg
Purity
>99.80%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01
1 unit tested for purity: >99.80% as printed
Conformity: Not assessable — every reported unit passed on all 8 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-02-04
8 results on the report · 3 rows computed from the per-unit values · 2 labs · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows
✓Purity · TotalWithin limits
>99.80 · 1 unit · USP <621> (procedural chapter)
✓Purity · NAD+Within limits
99.19% · 1 unit · USP <621> (procedural chapter)
✓Purity · NicotinamideWithin limits
0.81% · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit printed (>99.80%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay) · NAD+Within limits
655.83 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between unitsSingle measurement
1 unit printed (655.83 mg) · a between-unit spread needs two or more measured units
✓Heavy metalsWithin limits
all non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsPass
1 of 1 pass · 1 unit · USP <85> (procedural chapter)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
–ConformityNot assessable
every reported unit passed on all 8 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-02-04 · house check · agreement across all tests, unit to unit; QA approval corroborates
A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.