479 third-party lab reports published Code VETSDAY35 takes 35% off compound vials and capsules, enter it at checkout, and the build-a-kit discount stacks on top, applied automatically in the cart: 3% off 3–9 · 5% off 10–19 · 7% off 20+ units · solvents and lab supplies excluded. Ends Sunday night. For research use only. 99.65% median purity across 272 lots 257 / 257 lots pass sterility
Veterans Day sale
CodeVETSDAY35: 35% off compound vials and capsules
Build a kit3% at 3–9 · 5% at 10–19 · 7% at 20+ units
TogetherEnter the code at checkout; the build-a-kit discount is added automatically
ExcludesDiluents and solvents, lab supplies and equipment · Ends Sunday night

Code VETSDAY35 takes 35% off compound vials and capsules, enter it at checkout; the build-a-kit discount stacks on top: 3% at 3–9 · 5% at 10–19 · 7% at 20+ units.Diluents and solvents, lab supplies and equipment excluded · Ends Sunday night · Research use only

View catalogResearch use only

‹ Certificates NAD+ Lot 1669

Lab report (Certificate of Analysis, COA)

NAD+ · 1000 mg

Batch 1669 · tested February 24, 2026 (260 days ago) · released May 25, 2026 Discontinued variant

All tests passed

Batch
#1669 9 tests
Mass
1000 mg
Purity
>99.80%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01

1 unit tested for purity: >99.80% as printed

Conformity: Not assessable — every reported unit passed on all 8 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-02-24 · QA approval corroborates: Eagle Analytical Services Inc., Alison Eng, Quality Control Manager, 2026-01-22

Vanguard · issuing labEagle Analytical · sterility

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V260119-8 009

Reports for this lot

  1. Vanguard Laboratory this report · tested February 24, 2026 · 8 results · QA approvalVanguard · issuing labEagle Analytical · sterilityAll tests passed
  2. Vanguard Laboratory second report · tested February 4, 2026 · 8 results · QA approvalVanguard · issuing labEagle Analytical · sterilityAll tests passed

Test by test

8 results on the report · 3 rows computed from the per-unit values · 2 labs · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓Purity · TotalWithin limits
>99.80 · 1 unit · USP <621> (procedural chapter)
✓Purity · NAD+Within limits
98.87% · 1 unit · USP <621> (procedural chapter)
✓Purity · NicotinamideWithin limits
1.10% · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit printed (>99.80%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay) · NAD+Within limits
1,253.00 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between unitsSingle measurement
1 unit printed (1253 mg) · a between-unit spread needs two or more measured units
✓Heavy metalsWithin limits
all non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsPass
1 of 1 pass · 1 unit · USP <85> (procedural chapter)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
–ConformityNot assessable
every reported unit passed on all 8 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-02-24 · QA approval corroborates: Eagle Analytical Services Inc., Alison Eng, Quality Control Manager, 2026-01-22 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Lab reports for batch 1669

Combined report · Batch 1669

One file holding the Vanguard Laboratory and Eagle Analytical Services reports for this batch, assembled by our quality team from the labs' files.

3 pages · Vanguard report V260119-8 009

Open PDF
Download

Combined report · Batch 1669

One file holding the Vanguard Laboratory and Eagle Analytical Services reports for this batch, assembled by our quality team from the labs' files.

3 pages · Vanguard report V260119-8 008

Open PDF
Download

Tested by Vanguard Laboratory · Eagle Analytical Services Inc. · Released May 25, 2026

Permanent URL: https://peptidology.co/coa/nad-size-1000mg-lot-1669/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 37 times.