444 third-party lab reports published 3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Monday night. For research use only. 99.59% median purity across 251 lots Defense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified 239 / 239 lots pass sterility

‹ Certificates Thymosin Alpha 1 + Thymulin Lot 1668

Lab report (Certificate of Analysis, COA)

Thymosin Alpha 1 + Thymulin · 10mg + 10mg (20mg Total)

Batch 1668 · tested January 14, 2026 (248 days ago) · released May 25, 2026

All tests passed

Batch
#1668 9 tests
Mass
10mg + 10mg (20mg Total)
Purity
99.70%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01

1 unit tested for purity: 99.70% as printed

Conformity: Not assessable — every reported unit passed on all 7 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-01-14

Vanguard · issuing labEagle Analytical · sterility

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V251230-12 001

Reports for this lot

  1. Vanguard Laboratory this report · tested January 14, 2026 · 7 results · QA approvalVanguard · issuing labEagle Analytical · sterilityAll tests passed

Test by test

7 results on the report · 4 rows computed from the per-unit values · 2 labs · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows

PurityWithin limits
99.70% · 1 unit · USP <621> (procedural chapter)
Purity consistency between unitsSingle measurement
1 unit measured (99.70%) · a between-unit spread needs two or more measured units
Net peptide content (assay) · TA-1Within limits
10.72 mg · 1 unit · USP <621> (procedural chapter)
Net peptide content (assay) · ThymulinWithin limits
10.04 mg · 1 unit · USP <621> (procedural chapter)
Content consistency between units · TA-1Single measurement
1 unit printed (10.72 mg) · a between-unit spread needs two or more measured units
Content consistency between units · ThymulinSingle measurement
1 unit printed (10.04 mg) · a between-unit spread needs two or more measured units
Heavy metalsWithin limits
all non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)
Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
EndotoxinsPass
1 of 1 pass · 1 unit · USP <85> (procedural chapter) · limit <5.00 EU/mg (the lab's)
Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
ConformityNot assessable
every reported unit passed on all 7 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-01-14 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Tested by Vanguard Laboratory · Eagle Analytical Services Inc. · Released May 25, 2026

Permanent URL: https://peptidology.co/coa/thymosin-alpha-1-thymulin-lot-1668/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 6 times.