479 third-party lab reports published Code VETSDAY35 takes 35% off compound vials and capsules, enter it at checkout, and the build-a-kit discount stacks on top, applied automatically in the cart: 3% off 3–9 · 5% off 10–19 · 7% off 20+ units · solvents and lab supplies excluded. Ends Sunday night. For research use only. 99.65% median purity across 272 lots 257 / 257 lots pass sterility
Veterans Day sale
CodeVETSDAY35: 35% off compound vials and capsules
Build a kit3% at 3–9 · 5% at 10–19 · 7% at 20+ units
TogetherEnter the code at checkout; the build-a-kit discount is added automatically
ExcludesDiluents and solvents, lab supplies and equipment · Ends Sunday night

Code VETSDAY35 takes 35% off compound vials and capsules, enter it at checkout; the build-a-kit discount stacks on top: 3% at 3–9 · 5% at 10–19 · 7% at 20+ units.Diluents and solvents, lab supplies and equipment excluded · Ends Sunday night · Research use only

View catalogResearch use only

‹ Certificates Tesamorelin Lot 1672

Lab report (Certificate of Analysis, COA)

Tesamorelin · 10 mg

Batch 1672 · tested April 10, 2026 (215 days ago) · released August 26, 2026

All tests passed

Batch
#1672 10 tests
Mass
10 mg
Purity
99.12%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01

3 units tested for purity: 99.10 / 99.12 / 99.15% · spread 0.05 pt · net peptide content 5.47 / 6.22 / 6.37 mg

Conformity: Outside house limit — every reported unit passed on all 6 test rows · purity spread 0.05 pt within the house limit · content spread 15.0% is outside the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-04-10

Vanguard · issuing labEagle Analytical · sterility

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V260320-12 001

Notes

Content audit 9 Sep 2026: size all sizes → #738 10mg. Certificate prints: prints compound "Tesamorelin", lot "1672", lab id "V260320-12 001", content 5.47 / 6.22 / 6.37 mg (Assay, HPLC-UV/VI

Reports for this lot

  1. Vanguard Laboratory this report · tested April 10, 2026 · 6 results · QA approvalVanguard · issuing labEagle Analytical · sterilityAll tests passed

Test by test

6 results on the report · 3 rows computed from the per-unit values · 2 labs · each test used up to 3 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓PurityWithin limits
avg 99.12% · 3 units · USP <621> (procedural chapter)
✓Purity consistency between unitsWithin house limit
3 units: 99.10 / 99.12 / 99.15% · spread 0.05 pt · house limit · caution past 0.50 pt, outside past 1.00 pt · per-unit USP <621> results
✓Net peptide content (assay)Within limits
avg 6.02 mg · 3 units · USP <621> (procedural chapter)
×Content consistency between unitsOutside house limit
3 units: 5.47 / 6.22 / 6.37 mg · spread 0.90 mg, 15.0% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
✓Heavy metalsWithin limits
5 elements non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)

–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsPass
1 of 1 pass · 1 unit · USP <85> (procedural chapter) · limit <5.00 EU/mg (the lab's)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
×ConformityOutside house limit
every reported unit passed on all 6 test rows · purity spread 0.05 pt within the house limit · content spread 15.0% is outside the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-04-10 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Combined report · Batch 1672

One file holding the Vanguard Laboratory and Eagle Analytical Services reports for this batch, assembled by our quality team from the labs' files.

3 pages · Vanguard report V260320-12 001

Open PDF
Download

Tested by Vanguard Laboratory · Eagle Analytical Services Inc. · Released August 26, 2026 · Verify: go.peptidology.co/0fPepd

Permanent URL: https://peptidology.co/coa/tesamorelin-lot-1672/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 1 time.