444 third-party lab reports published3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Monday night. For research use only.99.59% median purity across 251 lotsDefense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified239 / 239 lots pass sterility444 third-party lab reports published3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Monday night. For research use only.99.59% median purity across 251 lotsDefense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified239 / 239 lots pass sterility
Batch 1363 · tested August 28, 2025 (388 days ago) · released May 25, 2026
All tests passed
Batch
#1363 8 tests
Mass
5 mg
Purity
>99.80%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01
1 unit tested for purity: >99.80% as printed
Conformity: Not assessable — every reported unit passed on all 5 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2025-08-28
Vanguard Laboratory this report · tested August 28, 2025 · 5 results · QA approvalVanguard · issuing labAll tests passed
Test by test
5 results on the report · 3 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows
✓PurityWithin limits
>99.80 · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit printed (>99.80%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay)Within limits
5.08 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between unitsSingle measurement
1 unit printed (5.08 mg) · a between-unit spread needs two or more measured units
✓Heavy metalsWithin limits
all non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsWithin limits
4.04 EU/mg · 1 unit · USP <85> (procedural chapter)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
–ConformityNot assessable
every reported unit passed on all 5 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2025-08-28 · house check · agreement across all tests, unit to unit; QA approval corroborates
A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.