479 third-party lab reports published Volume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded 99.65% median purity across 272 lots 257 / 257 lots pass sterility

‹ Certificates NAD+ Lot 1752

Lab report (Certificate of Analysis, COA)

NAD+ · 1066 mg

Batch 1752 · tested August 13, 2026 (83 days ago) · released September 3, 2026

All tests passed

Batch
#1752 14 of 15 tests
Mass
1000 mg · tested 1066 mg
Purity
>99.80%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01

3 units tested for purity, each printed >99.80% · net peptide content · nad+ 1065 / 1067 / 1066 mg

Conformity: Units agree — every reported unit passed on all 13 test rows · purity spread at most 0.20 pt within the house limit · content spread 0.2% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-08-13

Vanguard · issuing lab

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V260724-26 004

Reports for this lot

  1. Vanguard Laboratory this report · tested August 13, 2026 · 13 results · QA approvalVanguard · issuing labAll tests passed

Test by test

13 results on the report · 3 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 5 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓IdentityPass
53-84-9 · 1 unit · USP <621> (procedural chapter)
✓Purity · TotalWithin limits
>99.80, >99.80, >99.80 · 3 units · USP <621> (procedural chapter)
✓Purity · NAD+Within limits
avg 97.07% · 3 units · USP <621> (procedural chapter)
✓Purity · NicotinamideWithin limits
avg 2.93% · 3 units · USP <621> (procedural chapter)
✓Purity consistency between unitsWithin house limit
3 units, each above 99.80% (the lab's reporting bound) · units differ by at most 0.20 pt · house limit · caution past 0.50 pt, outside past 1.00 pt · per-unit USP <621> results
✓Net peptide content (assay) · NAD+Within limits
avg 1,066.00 mg · 3 units · USP <621> (procedural chapter)
✓Content consistency between unitsWithin house limit
3 units: 1065 / 1067 / 1066 mg · spread 2.00 mg, 0.2% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
✓Heavy metalsWithin limits
1 of 5 elements detected · 2 units · dose-scaled limits derived from USP <232> (limits chapter)

✓Residual solventsWithin limits
all non-detect · 1 unit · USP <467> (procedural chapter)
✓Trifluoroacetic acidWithin limits
all non-detect · 1 unit · house limit · ion chromatography, the lab's method; no compendial chapter for the method run · limit <0.10% (the lab's)
✓EndotoxinsPass
3 of 3 pass · 3 units · USP <85> (procedural chapter) · limit <5.00 EU/mg (the lab's)
✓Container closurePass
3 of 3 pass · 3 units · USP <1207> (informational chapter (1000-series))
✓SolubilityPass
3 of 3 pass · 3 units · house check · no compendial chapter
✓SterilityPass
5 of 5 pass · 5 units · USP <71> (procedural chapter)
✓Other · Adulterant screenWithin limits
all non-detect · 1 unit · no chapter named in the record; a screen
✓ConformityUnits agree
every reported unit passed on all 13 test rows · purity spread at most 0.20 pt within the house limit · content spread 0.2% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-08-13 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

First page of the Combined report · Batch 1752

Combined report · Batch 1752

One file holding the Vanguard Laboratory reports for this batch, combined by our system from the labs' own files.

3 pages · Vanguard report V260724-26 004

Open PDF
Download

Tested by Vanguard Laboratory · Released September 3, 2026 · Verify: go.peptidology.co/r7p38r

Permanent URL: https://peptidology.co/coa/nad-lot-1752/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 166 times.