493 third-party lab reports published Volume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded 99.61% median purity across 283 lots 263 / 263 lots pass sterility

‹ Certificates GLOW Blend Lot 1768

Lab report (Certificate of Analysis, COA)

GLOW Blend · 81.6mg/11.26mg/10.67mg

Batch 1768 · tested September 17, 2026 (65 days ago) · released September 22, 2026 Discontinued variant

All tests passed

Batch
#1768 15 tests
Mass
81.6mg/11.26mg/10.67mg
Purity
>99.50%
Labs and accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01 · issuing labEagle Analytical · ISO/IEC 17025:2017 (A2LA) · sterility

3 units tested for purity, each printed >99.50%

Conformity: Units agree — every reported unit passed on all 14 test rows · purity spread at most 0.50 pt within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-09-17

Vanguard · issuing labEagle Analytical · sterility

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V260828-46 001

Lab reports for this batch

  1. Vanguard Laboratory this report · 15 tests · purity >99.50 (as printed) · tested September 17, 2026Vanguard · issuing labEagle Analytical · sterilityAll tests passed

Test by test

14 results on the report · 5 rows computed from the per-unit values · 2 labs · each test used up to 5 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓IdentityPass
1 of 1 pass · 1 unit · USP <621> (procedural chapter)
✓PurityPass
3 of 3 pass · 3 units · USP <621> (procedural chapter)
✓Purity consistency between unitsWithin house limit
3 units, each above 99.50% (the lab's reporting bound) · units differ by at most 0.50 pt · house limit · caution past 0.50 pt, outside past 1.00 pt · per-unit USP <621> results
✓Net peptide content (assay) · GHK-CuWithin limits
75.46 mg · 1 unit · USP <621> (procedural chapter)
✓Net peptide content (assay) · BPC-157Within limits
10.23 mg · 1 unit · USP <621> (procedural chapter)
✓Net peptide content (assay) · TB-500Within limits
9.68 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between units · GHK-CuSingle measurement
1 unit printed (75.46 mg) · a between-unit spread needs two or more measured units
–Content consistency between units · BPC-157Single measurement
1 unit printed (10.23 mg) · a between-unit spread needs two or more measured units
–Content consistency between units · TB-500Single measurement
1 unit printed (9.68 mg) · a between-unit spread needs two or more measured units
✓Heavy metalsWithin limits
5 elements non-detect · 2 units · dose-scaled limits derived from USP <232> (limits chapter)

✓Residual solventsWithin limits
all non-detect · 1 unit · USP <467> (procedural chapter)
✓Trifluoroacetic acidWithin limits
all non-detect · 1 unit · house limit · ion chromatography, the lab's method; no compendial chapter for the method run · limit <0.10% (the lab's)
✓EndotoxinsPass
3 of 3 pass · 3 units · USP <85> (procedural chapter) · limit <5.00 EU/mg (the lab's)
✓Container closurePass
3 of 3 pass · 3 units · USP <1207> (informational chapter (1000-series))
✓SolubilityPass
3 of 3 pass · 3 units · house check · no compendial chapter
✓SterilityPass
5 of 5 pass · 5 units · USP <71> (procedural chapter)
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
✓Other · Adulterant screenWithin limits
all non-detect · 1 unit · no chapter named in the record; a screen
✓ConformityUnits agree
every reported unit passed on all 14 test rows · purity spread at most 0.50 pt within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-09-17 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Combined report · Batch 1768

One file holding the Vanguard Laboratory and Eagle Analytical Services reports for this batch, assembled by our quality team from the labs' files.

4 pages · Vanguard report V260828-46 001

Open PDF
Download

Tested by Vanguard Laboratory · Eagle Analytical Services Inc. · Released September 22, 2026 · Verify: go.peptidology.co/vQwpbh

Permanent URL: https://peptidology.co/coa/glow-blend-size-81-6mg-11-26mg-10-67mg-batch-1768-lot-1768/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 30 times.