489 third-party lab reports published 2 for the price of 1 on compound vials and capsules — put 2 of the same item and size in your cart and one is free, automatically. A single item is 30% off. Solvents included. Lab supplies and equipment excluded. Ends Monday, November 30. For research use only. 99.59% median purity across 281 lots Defense, VA, Federal and Public safety: verified accounts get an extra 5% on a single item, 35% in all, or 2 for the price of 1 · get verified 261 / 261 lots pass sterility

‹ Certificates GHK-Cu Copper Peptide Lot 1363

Lab report (Certificate of Analysis, COA)

GHK-Cu Copper Peptide · 100 mg

Batch 1363 · tested October 14, 2025 (404 days ago) · released May 26, 2026 Discontinued variant

All tests passed

Batch
#1363 9 tests
Mass
100 mg
Purity
>99.80%
Labs and accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01 · issuing labEagle Analytical · ISO/IEC 17025:2017 (A2LA) · sterility

1 unit tested for purity: >99.80% as printed

Conformity: Not assessable — every reported unit passed on all 6 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-10-14 · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-10-08 · QA approval corroborates: Eagle Analytical Services Inc., Alison Eng, 2025-10-04

Vanguard · issuing labEagle Analytical · sterility

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V250924-10 001

Lab reports for this batch

  1. Vanguard Laboratory this report · 9 tests · purity >99.80 (as printed) · tested October 14, 2025Vanguard · issuing labEagle Analytical · sterilityAll tests passed

Test by test

6 results on the report · 3 rows computed from the per-unit values · 2 labs · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓PurityWithin limits
>99.80 · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit printed (>99.80%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay)Within limits
101.54 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between unitsSingle measurement
1 unit printed (101.54 mg) · a between-unit spread needs two or more measured units
✓Heavy metalsWithin limits
5 elements non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)

–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsPass
1 of 1 pass · 1 unit · USP <85> (procedural chapter) · limit <0.05 EU/mg (the lab's)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
–ConformityNot assessable
every reported unit passed on all 6 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-10-14 · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-10-08 · QA approval corroborates: Eagle Analytical Services Inc., Alison Eng, 2025-10-04 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Combined report · Batch 1363

One file holding the Vanguard Laboratory and Eagle Analytical Services reports for this batch, assembled by our quality team from the labs' files.

3 pages · Vanguard report V250924-10 001

Open PDF
Download

Tested by Vanguard Laboratory · Eagle Analytical Services Inc. · Released May 26, 2026

Permanent URL: https://peptidology.co/coa/ghk-cu-copper-peptide-lot-1363/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 8 times.