449 third-party lab reports published Volume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded 99.59% median purity across 254 lots 242 / 242 lots pass sterility

‹ Certificates BPC-157, TB-500 (Blend) Lot V250214-1 004

Lab report (Certificate of Analysis, COA)

BPC-157, TB-500 (Blend) · 10 mg

Batch V250214-1 004 · tested February 24, 2025 (580 days ago) · released May 25, 2026 Discontinued variant

All tests passed

Batch
#V250214-1 004 7 tests
Mass
10 mg
Purity
99.73%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01

No tier shown — see the tests listed on the report

1 unit tested for purity: 99.73% as printed

Conformity: Not assessable — every reported unit passed on all 5 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-02-24 · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-03-03

Vanguard · issuing lab

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V250214-1 004

Reports for this lot

  1. Vanguard Laboratory this report · tested February 24, 2025 · 5 results · QA approvalVanguard · issuing labAll tests passed

Test by test

5 results on the report · 4 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓PurityWithin limits
99.73% · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit measured (99.73%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay) · BPC-157Within limits
5.60 mg · 1 unit · USP <621> (procedural chapter)
✓Net peptide content (assay) · TB-500Within limits
5.09 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between units · BPC-157Single measurement
1 unit printed (5.60 mg) · a between-unit spread needs two or more measured units
–Content consistency between units · TB-500Single measurement
1 unit printed (5.09 mg) · a between-unit spread needs two or more measured units
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsWithin limits
<0.05 · 1 unit · USP <85> (procedural chapter) · limit <0.05 EU/mL (the lab's)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
–ConformityNot assessable
every reported unit passed on all 5 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-02-24 · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-03-03 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Tested by Vanguard Laboratory · Released May 25, 2026

Permanent URL: https://peptidology.co/coa/bpc-157-tb-500-blend-lot-v250214-1-004/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 4 times.