479 third-party lab reports published Code VETSDAY35 takes 35% off compound vials and capsules, enter it at checkout, and the build-a-kit discount stacks on top, applied automatically in the cart: 3% off 3–9 · 5% off 10–19 · 7% off 20+ units · solvents and lab supplies excluded. Ends Sunday night. For research use only. 99.65% median purity across 272 lots 257 / 257 lots pass sterility
Veterans Day sale
CodeVETSDAY35: 35% off compound vials and capsules
Build a kit3% at 3–9 · 5% at 10–19 · 7% at 20+ units
TogetherEnter the code at checkout; the build-a-kit discount is added automatically
ExcludesDiluents and solvents, lab supplies and equipment · Ends Sunday night

Code VETSDAY35 takes 35% off compound vials and capsules, enter it at checkout; the build-a-kit discount stacks on top: 3% at 3–9 · 5% at 10–19 · 7% at 20+ units.Diluents and solvents, lab supplies and equipment excluded · Ends Sunday night · Research use only

View catalogResearch use only

‹ Certificates BPC-157 Lot BPC 10mg 120008

Lab report (Certificate of Analysis, COA)

BPC-157 · 10 mg

Batch BPC 10mg 120008 · tested February 8, 2025 (641 days ago) · released May 25, 2026

All tests passed

Batch
#BPC 10mg 120008 7 tests
Mass
10 mg
Purity
99.42%

No tier shown — see the tests listed on the report

1 unit tested for purity: 99.416% as printed

Conformity: Not assessable — every reported unit passed on all 7 test rows · QA approval corroborates: TrustPointe Analytics LLC, Joshua Lust (Managing Director); Ashlee Lust (President), 2025-02-08 · QA approval corroborates: TrustPointe Analytics LLC, Joshua Lust (Managing Director); Ashlee Lust (President), 2025-02-21

TrustPointe · issuing lab

Notes

Content audit 9 Sep 2026: lab id (blank) → SPL-0359. Certificate prints: prints compound "BPC-157 10mg", lot "BPC 10mg 120008", lab id "SPL-0359", content 11.23

Reports for this lot

  1. TrustPointe Analytics LLC this report · tested February 8, 2025 · 7 results · QA approvalTrustPointe · issuing labAll tests passed

Test by test

7 results on the report · 3 rows computed from the per-unit values · 1 lab · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓IdentityWithin limits
1.00 · 1 unit · USP <621> (procedural chapter)
✓IdentityWithin limits
1,000.00 · 1 unit · USP <621> (procedural chapter)
✓Purity · BPC-157Within limits
99.42% · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit measured (99.416%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay) · BPC-157Within limits
11.23 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between unitsSingle measurement
1 unit printed (11.23 mg) · a between-unit spread needs two or more measured units
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
✓Other · BPC-157 Coelution ControlWithin limits
999.00 · 1 unit · no chapter named in the record; a screen
✓Other · BPC-157 System SuitabilityWithin limits
1.10 %RSD · 1 unit · no chapter named in the record; a screen
–ConformityNot assessable
every reported unit passed on all 7 test rows · QA approval corroborates: TrustPointe Analytics LLC, Joshua Lust (Managing Director); Ashlee Lust (President), 2025-02-08 · QA approval corroborates: TrustPointe Analytics LLC, Joshua Lust (Managing Director); Ashlee Lust (President), 2025-02-21 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Tested by TrustPointe Analytics LLC · Released May 25, 2026