444 third-party lab reports published3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Monday night. For research use only.99.59% median purity across 251 lotsDefense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified239 / 239 lots pass sterility444 third-party lab reports published3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Monday night. For research use only.99.59% median purity across 251 lotsDefense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified239 / 239 lots pass sterility
Batch KBC0012026-01 · tested March 11, 2026 (193 days ago) · released May 28, 2026 Discontinued variant
All tests passed
Batch
#KBC0012026-01 5 tests
Mass
BPC-157 371mcg + KPV 464mcg
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01
No tier shown — see the tests listed on the report
Conformity: Not assessable — every reported unit passed on all 4 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-03-11
Content audit 9 Sep 2026: lab id (blank) → V260218-2 001. Certificate prints: prints compound "BPC-157/KPV", lot "KBC0012026-01", lab id "V260218-2 001", content 371 mcg/unit (BPC-157) / 464 mcg/unit (K
Reports for this lot
Vanguard Laboratory this report · tested March 11, 2026 · 4 results · QA approvalVanguard · issuing labAll tests passed
Test by test
4 results on the report · 4 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows
–Purity consistency between unitsNot on this report
no purity result printed on this lab report
✓Net peptide content (assay) · KPVWithin limits
464.00 mcg/unit · 1 unit · USP <621> (procedural chapter)
371.00 mcg/unit · 1 unit · USP <621> (procedural chapter)
–Content consistency between units · KPVSingle measurement
1 unit printed (464 mcg/unit) · a between-unit spread needs two or more measured units
–Content consistency between units · BPC-157Single measurement
1 unit printed (371 mcg/unit) · a between-unit spread needs two or more measured units
✓Heavy metalsWithin limits
4 elements non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)
Element
Measured
Limit
Verdict
Arsenic (As)
ND (<0.02 ppm)
15,000 ppm
Not detected
Cadmium (Cd)
ND (<0.01 ppm)
2,000 ppm
Not detected
Lead (Pb)
ND (<0.02 ppm)
5,000 ppm
Not detected
Mercury (Hg)
ND (<0.01 ppm)
3,000 ppm
Not detected
Dose-scaled limits derived from USP <232> for arsenic, cadmium, lead, mercury and chromium, using this product's configured reference quantity of 1.00 mg.
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓MicrobialWithin limits
20.00 CFU/g · 1 unit · no chapter named in the record; a screen
–ConformityNot assessable
every reported unit passed on all 4 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-03-11 · house check · agreement across all tests, unit to unit; QA approval corroborates
A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.