467 third-party lab reports published 3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Saturday, October 31. For research use only. 99.65% median purity across 265 lots Defense, VA, Federal and Public safety: your verified pricing stays on and stacks with 3 for the price of 2, up to the 43% order cap · get verified 250 / 250 lots pass sterility

‹ Certificates BPC-157 + KPV Capsules Lot 1788

Lab report (Certificate of Analysis, COA)

BPC-157 + KPV Capsules · BPC-157 0.93mg + KPV 0.95mg

Batch 1788 · tested October 6, 2026 (4 days ago) · released October 7, 2026 Discontinued variant

All tests passed

Batch
#1788 11 tests
Mass
BPC-157 0.93mg + KPV 0.95mg
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01

No tier shown — see the tests listed on the report

net peptide content · bpc-157 0.99 / 0.93 / 0.87 mg · net peptide content · kpv 0.73 / 1.18 / 0.95 mg

Conformity: Outside house limit — every reported unit passed on all 10 test rows · content spread (BPC-157) 12.9% is outside the house limit · content spread (KPV) 47.2% is outside the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2026-10-06

Vanguard · issuing lab

Reports for this lot

  1. Vanguard Laboratory this report · tested October 6, 2026 · 10 results · QA approvalVanguard · issuing labAll tests passed

Test by test

10 results on the report · 4 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 3 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓IdentityPass
1 of 1 pass · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsNot on this report
no purity result printed on this lab report
✓Net peptide content (assay) · BPC-157Within limits
avg 0.93 mg · 3 units · USP <621> (procedural chapter)
✓Net peptide content (assay) · KPVWithin limits
avg 0.95 mg · 3 units · USP <621> (procedural chapter)
×Content consistency between units · BPC-157Outside house limit
3 units: 0.99 / 0.93 / 0.87 mg · spread 0.12 mg, 12.9% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
×Content consistency between units · KPVOutside house limit
3 units: 0.73 / 1.18 / 0.95 mg · spread 0.45 mg, 47.2% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
✓Heavy metalsWithin limits
5 elements non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)

✓Residual solventsWithin limits
all non-detect · 1 unit · USP <467> (procedural chapter)
✓Trifluoroacetic acidWithin limits
all non-detect · 1 unit · house limit · ion chromatography, the lab's method; no compendial chapter for the method run · limit <0.10% (the lab's)
✓Container closurePass
1 of 1 pass · 1 unit · USP <1207> (informational chapter (1000-series))
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓MicrobialPass
1 of 1 pass · 1 unit · no chapter named in the record; a screen
✓Other · Adulterant screenWithin limits
all non-detect · 1 unit · no chapter named in the record; a screen
✓Other · DissolutionPass
1 of 1 pass · 1 unit · no chapter named in the record; a screen
×ConformityOutside house limit
every reported unit passed on all 10 test rows · content spread (BPC-157) 12.9% is outside the house limit · content spread (KPV) 47.2% is outside the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2026-10-06 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Tested by Vanguard Laboratory · Released October 7, 2026 · Verify: go.peptidology.co/ayLq7U

Permanent URL: https://peptidology.co/coa/bpc-157-kpv-capsules-size-bpc-157-0-93mg-kpv-0-95mg-batch-1788-lot-1788/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 5 times.