444 third-party lab reports published3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Monday night. For research use only.99.59% median purity across 251 lotsDefense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified239 / 239 lots pass sterility444 third-party lab reports published3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Monday night. For research use only.99.59% median purity across 251 lotsDefense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified239 / 239 lots pass sterility
Batch 1730 · tested August 27, 2026 (24 days ago) · released September 10, 2026
All tests passed
Batch
#1730 6 tests
Mass
16.80 mg/unit
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01
No tier shown — see the tests listed on the report
net peptide content 17.66 / 16.25 / 16.48 mg
Conformity: Caution — every reported unit passed on all 4 test rows · content spread 8.4% is in the caution band · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-08-27
Vanguard Laboratory this report · tested August 27, 2026 · 4 results · QA approvalVanguard · issuing labAll tests passed
Test by test
4 results on the report · 3 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 3 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows
✓IdentityPass
1 of 1 pass · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsNot on this report
3 units: 17.66 / 16.25 / 16.48 mg · spread 1.41 mg, 8.4% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
✓Heavy metalsWithin limits
1 of 5 elements detected · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)
Element
Measured
Limit
Verdict
Chromium (Cr)
ND (<0.05 ppm)
1,100,000 ppm
Not detected
Arsenic (As)
ND (<0.01 ppm)
15,000 ppm
Not detected
Cadmium (Cd)
ND (<0.01 ppm)
2,000 ppm
Not detected
Lead (Pb)
0.02 ppm
5,000 ppm
Within limit
Mercury (Hg)
ND (<0.01 ppm)
3,000 ppm
Not detected
Dose-scaled limits derived from USP <232> for arsenic, cadmium, lead, mercury and chromium, using this product's configured reference quantity of 1.00 mg.
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓MicrobialPass
1 of 1 pass · 1 unit · no chapter named in the record; a screen
!ConformityCaution
every reported unit passed on all 4 test rows · content spread 8.4% is in the caution band · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-08-27 · house check · agreement across all tests, unit to unit; QA approval corroborates
A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.