449 third-party lab reports published Volume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded 99.59% median purity across 254 lots 242 / 242 lots pass sterility

‹ Certificates MOTS-c Lot 1356

Lab report (Certificate of Analysis, COA)

MOTS-c · 7 mg

Batch 1356 · tested June 17, 2025 (467 days ago) · released September 8, 2026 Discontinued variant

All tests passed

Batch
#1356 8 tests
Mass
7 mg
Purity
99.65%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01

1 unit tested for purity: 99.65% as printed

Conformity: Not assessable — every reported unit passed on all 5 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2025-06-17

Vanguard · issuing lab

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V250529-9 003

Notes

Content audit 9 Sep 2026: size all sizes → #30753 7mg. Certificate prints: prints compound "MOTS-c", lot "1356", lab id "V250529-9 003", content 6.64 mg (Assay result; declared Amount w

Reports for this lot

  1. Vanguard Laboratory this report · tested June 17, 2025 · 5 results · QA approvalVanguard · issuing labAll tests passed

Test by test

5 results on the report · 3 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓PurityWithin limits
99.65% · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit measured (99.65%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay)Within limits
6.64 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between unitsSingle measurement
1 unit printed (6.64 mg) · a between-unit spread needs two or more measured units
✓Heavy metalsWithin limits
6 elements non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)

–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsWithin limits
all non-detect · 1 unit · USP <85> (procedural chapter) · limit <0.05 EU/mL (the lab's)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
–ConformityNot assessable
every reported unit passed on all 5 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2025-06-17 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Tested by Vanguard Laboratory · Released September 8, 2026 · Verify: go.peptidology.co/fCC8kX

Permanent URL: https://peptidology.co/coa/mots-c/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 4 times.