479 third-party lab reports published Code VETSDAY35 takes 35% off compound vials and capsules, enter it at checkout, and the build-a-kit discount stacks on top, applied automatically in the cart: 3% off 3–9 · 5% off 10–19 · 7% off 20+ units · solvents and lab supplies excluded. Ends Sunday night. For research use only. 99.65% median purity across 272 lots 257 / 257 lots pass sterility
Veterans Day sale
CodeVETSDAY35: 35% off compound vials and capsules
Build a kit3% at 3–9 · 5% at 10–19 · 7% at 20+ units
TogetherEnter the code at checkout; the build-a-kit discount is added automatically
ExcludesDiluents and solvents, lab supplies and equipment · Ends Sunday night

Code VETSDAY35 takes 35% off compound vials and capsules, enter it at checkout; the build-a-kit discount stacks on top: 3% at 3–9 · 5% at 10–19 · 7% at 20+ units.Diluents and solvents, lab supplies and equipment excluded · Ends Sunday night · Research use only

View catalogResearch use only

‹ Certificates CJC No DAC IPA Blend Lot 1355

Lab report (Certificate of Analysis, COA)

CJC No DAC IPA Blend · 5mg each (10mg total)

Batch 1355 · tested April 14, 2025 (576 days ago) · released September 8, 2026

All tests passed

Batch
#1355 7 tests
Mass
5mg each (10mg total)
Purity
99.44%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01

No tier shown — see the tests listed on the report

1 unit tested for purity: 99.44% as printed

Conformity: Not assessable — every reported unit passed on all 5 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-04-14

Vanguard · issuing lab

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V250331-1 002

Notes

Content audit 9 Sep 2026: lot 01-014-PD-1355 → 1355; size all sizes → #686 5mg-each-10mg-total. Certificate prints: prints compound "CJC-1295 (No Dac) & Ipamorelin", lot "01-014-PD-1355", lab id "V250331-1 002", content CJC-1295: 5.01 mg / Ipamorelin: 4.99 mg

Reports for this lot

  1. Vanguard Laboratory this report · tested April 14, 2025 · 5 results · QA approvalVanguard · issuing labAll tests passed

Test by test

5 results on the report · 4 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓PurityWithin limits
99.44% · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit measured (99.44%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay) · CJC-1295Within limits
5.01 mg · 1 unit · USP <621> (procedural chapter)
✓Net peptide content (assay) · IpamorelinWithin limits
4.99 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between units · CJC-1295Single measurement
1 unit printed (5.01 mg) · a between-unit spread needs two or more measured units
–Content consistency between units · IpamorelinSingle measurement
1 unit printed (4.99 mg) · a between-unit spread needs two or more measured units
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsWithin limits
all non-detect · 1 unit · USP <85> (procedural chapter) · limit <0.05 EU/mL (the lab's)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
–ConformityNot assessable
every reported unit passed on all 5 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-04-14 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Tested by Vanguard Laboratory · Released September 8, 2026 · Verify: go.peptidology.co/XF3z22

Permanent URL: https://peptidology.co/coa/cjc-no-dac-ipa-blend/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 5 times.