444 third-party lab reports published3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Monday night. For research use only.99.59% median purity across 251 lotsDefense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified239 / 239 lots pass sterility444 third-party lab reports published3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Monday night. For research use only.99.59% median purity across 251 lotsDefense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified239 / 239 lots pass sterility
Batch 1766 · tested August 31, 2026 (19 days ago) · released September 8, 2026
All tests passed
Batch
#1766 14 of 15 tests
Mass
1 mg · tested 0.83 mg
Purity
99.80%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01
3 units tested for purity: 99.80 / 99.80 / 99.80% · spread 0.00 pt · net peptide content 0.82 / 0.83 / 0.84 mg
Conformity: Units agree — every reported unit passed on all 11 test rows · purity spread 0.00 pt within the house limit · content spread 2.4% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-08-31
Content audit 9 Sep 2026: size all sizes → #57247 1mg-batch-1766. Certificate prints: prints compound "IGF-LR3", lot "1766", lab id "V260814-25 001", content 0.82 / 0.83 / 0.84
Reports for this lot
Vanguard Laboratory this report · tested August 31, 2026 · 11 results · QA approvalVanguard · issuing labAll tests passed
Test by test
11 results on the report · 3 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 5 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows
✓IdentityPass
1 of 1 pass · 1 unit · USP <621> (procedural chapter)
✓PurityWithin limits
avg 99.80% · 3 units · USP <621> (procedural chapter)
✓Purity consistency between unitsWithin house limit
3 units: 99.80 / 99.80 / 99.80% · spread 0.00 pt · house limit · caution past 0.50 pt, outside past 1.00 pt · per-unit USP <621> results
✓Content consistency between unitsWithin house limit
3 units: 0.82 / 0.83 / 0.84 mg · spread 0.02 mg, 2.4% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
✓Heavy metalsWithin limits
5 elements non-detect · 2 units · dose-scaled limits derived from USP <232> (limits chapter)
Element
Measured
Limit
Verdict
Chromium (Cr)
ND (<0.05 ppm)
1,100,000 ppm
Not detected
Arsenic (As)
ND (<0.01 ppm)
15,000 ppm
Not detected
Cadmium (Cd)
ND (<0.01 ppm)
2,000 ppm
Not detected
Lead (Pb)
ND (<0.02 ppm)
5,000 ppm
Not detected
Mercury (Hg)
ND (<0.01 ppm)
3,000 ppm
Not detected
Dose-scaled limits derived from USP <232> for arsenic, cadmium, lead, mercury and chromium, using this product's configured reference quantity of 1.00 mg.
✓Residual solventsWithin limits
all non-detect · 1 unit · USP <467> (procedural chapter)
✓Trifluoroacetic acidWithin limits
all non-detect · 1 unit · house limit · ion chromatography, the lab's method; no compendial chapter for the method run · limit <0.10% (the lab's)
✓EndotoxinsPass
3 of 3 pass · 3 units · USP <85> (procedural chapter) · limit <5.00 EU/mg (the lab's)
✓Container closurePass
3 of 3 pass · 3 units · USP <1207> (informational chapter (1000-series))
✓SolubilityPass
3 of 3 pass · 3 units · house check · no compendial chapter
✓SterilityPass
5 of 5 pass · 5 units · USP <71> (procedural chapter)
✓Other · Adulterant screenWithin limits
all non-detect · 1 unit · no chapter named in the record; a screen
✓ConformityUnits agree
every reported unit passed on all 11 test rows · purity spread 0.00 pt within the house limit · content spread 2.4% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-08-31 · house check · agreement across all tests, unit to unit; QA approval corroborates
A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.