444 third-party lab reports published 3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Monday night. For research use only. 99.59% median purity across 251 lots Defense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified 239 / 239 lots pass sterility

‹ Certificates GLOW Blend Lot 1744

Lab report (Certificate of Analysis, COA)

GLOW Blend · 62.71mg/11.84mg/13.65mg

Batch 1744 · tested September 2, 2026 (18 days ago) · released September 8, 2026

All tests passed

Batch
#1744 13 of 15 tests
Mass
62.71mg/11.84mg/13.65mg
Purity
>99.50%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01

3 units tested for purity, each printed >99.50%

Conformity: Units agree — every reported unit passed on all 13 test rows · purity spread at most 0.50 pt within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-09-02

Vanguard · issuing lab

Reports for this lot

  1. Vanguard Laboratory this report · tested September 2, 2026 · 13 results · QA approvalVanguard · issuing labAll tests passed

Test by test

13 results on the report · 5 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 5 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows

IdentityPass
1 of 1 pass · 1 unit · USP <621> (procedural chapter)
PurityPass
3 of 3 pass · 3 units · USP <621> (procedural chapter)
Purity consistency between unitsWithin house limit
3 units, each above 99.50% (the lab's reporting bound) · units differ by at most 0.50 pt · house limit · caution past 0.50 pt, outside past 1.00 pt · per-unit USP <621> results
Net peptide content (assay) · GHK-CuWithin limits
62.28 mg · 1 unit · USP <621> (procedural chapter)
Net peptide content (assay) · BPC-157Within limits
11.82 mg · 1 unit · USP <621> (procedural chapter)
Net peptide content (assay) · TB-500Within limits
13.58 mg · 1 unit · USP <621> (procedural chapter)
Content consistency between units · GHK-CuSingle measurement
1 unit printed (62.28 mg) · a between-unit spread needs two or more measured units
Content consistency between units · BPC-157Single measurement
1 unit printed (11.82 mg) · a between-unit spread needs two or more measured units
Content consistency between units · TB-500Single measurement
1 unit printed (13.58 mg) · a between-unit spread needs two or more measured units
Heavy metalsWithin limits
5 elements non-detect · 2 units · dose-scaled limits derived from USP <232> (limits chapter)

Residual solventsWithin limits
all non-detect · 1 unit · USP <467> (procedural chapter)
Trifluoroacetic acidWithin limits
all non-detect · 1 unit · house limit · ion chromatography, the lab's method; no compendial chapter for the method run · limit <0.10% (the lab's)
EndotoxinsPass
3 of 3 pass · 3 units · USP <85> (procedural chapter) · limit <5.00 EU/mg (the lab's)
Container closurePass
3 of 3 pass · 3 units · USP <1207> (informational chapter (1000-series))
SolubilityPass
3 of 3 pass · 3 units · house check · no compendial chapter
SterilityPass
5 of 5 pass · 5 units · USP <71> (procedural chapter)
Other · Adulterant screenWithin limits
all non-detect · 1 unit · no chapter named in the record; a screen
ConformityUnits agree
every reported unit passed on all 13 test rows · purity spread at most 0.50 pt within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-09-02 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Tested by Vanguard Laboratory · Released September 8, 2026 · Verify: go.peptidology.co/Oy4pgI

Permanent URL: https://peptidology.co/coa/glow-blend-size-10mg-10mg-50mg70mg-batch-1744-lot-1744/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 3 times.