489 third-party lab reports published2 for the price of 1 on compound vials and capsules — put 2 of the same item and size in your cart and one is free, automatically. A single item is 30% off. Solvents included. Lab supplies and equipment excluded. Ends Monday, November 30. For research use only.99.59% median purity across 281 lotsDefense, VA, Federal and Public safety: verified accounts get an extra 5% on a single item, 35% in all, or 2 for the price of 1 · get verified261 / 261 lots pass sterility489 third-party lab reports published2 for the price of 1 on compound vials and capsules — put 2 of the same item and size in your cart and one is free, automatically. A single item is 30% off. Solvents included. Lab supplies and equipment excluded. Ends Monday, November 30. For research use only.99.59% median purity across 281 lotsDefense, VA, Federal and Public safety: verified accounts get an extra 5% on a single item, 35% in all, or 2 for the price of 1 · get verified261 / 261 lots pass sterility
2 units tested for purity, each printed >99.80% · net peptide content 54.70 / 56.44 mg
Conformity: Units agree — every reported unit passed on all 6 test rows · purity spread at most 0.20 pt within the house limit · content spread 3.1% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2026-03-10
6 results on the report · 3 rows computed from the per-unit values · 2 labs · each test used up to 2 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows
✓PurityWithin limits
>99.80, >99.80 · 2 units · USP <621> (procedural chapter)
✓Purity consistency between unitsWithin house limit
2 units, each above 99.80% (the lab's reporting bound) · units differ by at most 0.20 pt · house limit · caution past 0.50 pt, outside past 1.00 pt · per-unit USP <621> results
✓Content consistency between unitsWithin house limit
2 units: 54.70 / 56.44 mg · spread 1.74 mg, 3.1% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
✓Heavy metalsWithin limits
5 elements non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)
Element
Measured
Limit
Verdict
Chromium (Cr)
ND (<0.05 ppm)
1,100,000 ppm
Not detected
Arsenic (As)
ND (<0.01 ppm)
15,000 ppm
Not detected
Cadmium (Cd)
ND (<0.01 ppm)
2,000 ppm
Not detected
Lead (Pb)
ND (<0.02 ppm)
5,000 ppm
Not detected
Mercury (Hg)
ND (<0.01 ppm)
3,000 ppm
Not detected
Dose-scaled limits derived from USP <232> for arsenic, cadmium, lead, mercury and chromium, using this product's configured reference quantity of 1.00 mg.
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsPass
1 of 1 pass · 1 unit · USP <85> (procedural chapter) · limit <5.00 EU/mg (the lab's)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
✓ConformityUnits agree
every reported unit passed on all 6 test rows · purity spread at most 0.20 pt within the house limit · content spread 3.1% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2026-03-10 · house check · agreement across all tests, unit to unit; QA approval corroborates
A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.
Combined report · Batch 1671
One file holding the Vanguard Laboratory and Eagle Analytical Services reports for this batch, assembled by our quality team from the labs' files.