449 third-party lab reports published 3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Tuesday night. For research use only. 99.58% median purity across 254 lots Defense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified 242 / 242 lots pass sterility

‹ Certificates MT1 Lot 1680

Lab report (Certificate of Analysis, COA)

MT1 · 10 mg

Batch 1680 · tested May 22, 2026 (123 days ago) · released June 2, 2026 Discontinued variant

All tests passed

Batch
#1680 13 tests
Mass
10 mg
Purity
99.25%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01

3 units tested for purity: 99.25 / 99.24 / 99.28% · spread 0.04 pt · net peptide content 9.93 / 9.96 / 9.95 mg

Conformity: Units agree — every reported unit passed on all 9 test rows · purity spread 0.04 pt within the house limit · content spread 0.3% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-05-22

Vanguard · issuing labEagle Analytical · sterility

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V260513-13 002

Notes

Content audit 9 Sep 2026: lab id (blank) → V260513-13 002. Certificate prints: prints compound "Melanotan-1", lot "1680", lab id "V260513-13 002", content 9.93 / 9.96 / 9.95

Reports for this lot

  1. Vanguard Laboratory this report · tested May 22, 2026 · 9 results · QA approvalVanguard · issuing labEagle Analytical · sterilityAll tests passed

Test by test

9 results on the report · 3 rows computed from the per-unit values · 2 labs · each test used up to 3 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows

PurityWithin limits
avg 99.26% · 3 units · USP <621> (procedural chapter)
Purity consistency between unitsWithin house limit
3 units: 99.25 / 99.24 / 99.28% · spread 0.04 pt · house limit · caution past 0.50 pt, outside past 1.00 pt · per-unit USP <621> results
Net peptide content (assay)Within limits
avg 9.95 mg · 3 units · USP <621> (procedural chapter)
Content consistency between unitsWithin house limit
3 units: 9.93 / 9.96 / 9.95 mg · spread 0.03 mg, 0.3% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
Heavy metalsWithin limits
all non-detect · 2 units · dose-scaled limits derived from USP <232> (limits chapter)
Residual solventsWithin limits
all non-detect · 1 unit · USP <467> (procedural chapter)
Trifluoroacetic acidWithin limits
all non-detect · 1 unit · house limit · ion chromatography, the lab's method; no compendial chapter for the method run · limit <0.10% (the lab's)
EndotoxinsPass
3 of 3 pass · 3 units · USP <85> (procedural chapter) · limit <5.00 EU/mg (the lab's)
Container closurePass
3 of 3 pass · 3 units · USP <1207> (informational chapter (1000-series))
SolubilityPass
3 of 3 pass · 3 units · house check · no compendial chapter
SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
ConformityUnits agree
every reported unit passed on all 9 test rows · purity spread 0.04 pt within the house limit · content spread 0.3% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-05-22 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Tested by Vanguard Laboratory · Eagle Analytical Services Inc. · Released June 2, 2026

Permanent URL: https://peptidology.co/coa/mt1-lot-1680/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 3 times.