449 third-party lab reports publishedVolume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded99.59% median purity across 254 lots242 / 242 lots pass sterility449 third-party lab reports publishedVolume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded99.59% median purity across 254 lots242 / 242 lots pass sterility
Batch 1668 · tested December 30, 2025 (271 days ago) · released May 25, 2026
All tests passed
Batch
#1668 9 tests
Mass
10 mg
Purity
99.67%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01
1 unit tested for purity: 99.67% as printed
Conformity: Not assessable — every reported unit passed on all 6 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2025-12-30
6 results on the report · 3 rows computed from the per-unit values · 2 labs · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows
✓PurityWithin limits
99.67% · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit measured (99.67%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay)Within limits
11.01 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between unitsSingle measurement
1 unit printed (11.01 mg) · a between-unit spread needs two or more measured units
✓Heavy metalsWithin limits
2 of 5 elements detected · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)
Element
Measured
Limit
Verdict
Chromium (Cr)
0.08 ppm
1,100,000 ppm
Within limit
Arsenic (As)
ND (<0.01 ppm)
15,000 ppm
Not detected
Cadmium (Cd)
ND (<0.01 ppm)
2,000 ppm
Not detected
Lead (Pb)
0.03 ppm
5,000 ppm
Within limit
Mercury (Hg)
ND (<0.01 ppm)
3,000 ppm
Not detected
Dose-scaled limits derived from USP <232> for arsenic, cadmium, lead, mercury and chromium, using this product's configured reference quantity of 1.00 mg.
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsWithin limits
4.14 EU/mg · 1 unit · USP <85> (procedural chapter)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
–ConformityNot assessable
every reported unit passed on all 6 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2025-12-30 · house check · agreement across all tests, unit to unit; QA approval corroborates
A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.