449 third-party lab reports published Volume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded 99.59% median purity across 254 lots 242 / 242 lots pass sterility

‹ Certificates GH Fragment 176-191 Lot 1200014

Lab report (Certificate of Analysis, COA)

GH Fragment 176-191 · 5 mg

Batch 1200014 · tested April 8, 2025 (537 days ago) · released May 25, 2026 Discontinued variant

All tests passed

Batch
#1200014 7 tests
Mass
5 mg
Purity
99.37%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01

No tier shown — see the tests listed on the report

1 unit tested for purity: 99.37% as printed

Conformity: Not assessable — every reported unit passed on all 4 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-04-08

Vanguard · issuing lab

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V250319-5 003

Notes

Content audit 9 Sep 2026: lab id (blank) → V250319-5 003. Certificate prints: prints compound "HGH Fragment 176-191", lot "1200014", lab id "V250319-5 003", content 5.16

Reports for this lot

  1. Vanguard Laboratory this report · tested April 8, 2025 · 4 results · QA approvalVanguard · issuing labAll tests passed

Test by test

4 results on the report · 3 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓PurityWithin limits
99.37% · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit measured (99.37%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay)Within limits
5.16 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between unitsSingle measurement
1 unit printed (5.16 mg) · a between-unit spread needs two or more measured units
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsWithin limits
<0.05 · 1 unit · USP <85> (procedural chapter) · limit <0.05 EU/mL (the lab's)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
–ConformityNot assessable
every reported unit passed on all 4 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-04-08 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Tested by Vanguard Laboratory · Released May 25, 2026

Permanent URL: https://peptidology.co/coa/gh-fragment-176-191-lot-1200014/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 4 times.