449 third-party lab reports published Volume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded 99.59% median purity across 254 lots 242 / 242 lots pass sterility

‹ Certificates CJC No DAC IPA Blend Lot 1668

Lab report (Certificate of Analysis, COA)

CJC No DAC IPA Blend · 5mg each (10mg total)

Batch 1668 · tested January 6, 2026 (264 days ago) · released May 25, 2026

All tests passed

Batch
#1668 9 tests
Mass
5mg each (10mg total)
Purity
>99.80%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01

1 unit tested for purity: >99.80% as printed

Conformity: Not assessable — every reported unit passed on all 7 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-01-06

Vanguard · issuing labEagle Analytical · sterility

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V251218-9 001

Reports for this lot

  1. Vanguard Laboratory this report · tested January 6, 2026 · 7 results · QA approvalVanguard · issuing labEagle Analytical · sterilityAll tests passed

Test by test

7 results on the report · 4 rows computed from the per-unit values · 2 labs · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓PurityWithin limits
>99.80 · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit printed (>99.80%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay) · IpamorelinWithin limits
5.04 mg · 1 unit · USP <621> (procedural chapter)
✓Net peptide content (assay) · CJC-1295Within limits
4.66 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between units · IpamorelinSingle measurement
1 unit printed (5.04 mg) · a between-unit spread needs two or more measured units
–Content consistency between units · CJC-1295Single measurement
1 unit printed (4.66 mg) · a between-unit spread needs two or more measured units
✓Heavy metalsWithin limits
all non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsWithin limits
11.40 EU/mg · 1 unit · USP <85> (procedural chapter)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
–ConformityNot assessable
every reported unit passed on all 7 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-01-06 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Tested by Vanguard Laboratory · Eagle Analytical Services Inc. · Released May 25, 2026

Permanent URL: https://peptidology.co/coa/cjc-no-dac-ipa-blend-lot-1668/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 5 times.