489 third-party lab reports published Defense, VA, Federal and Public safety: verified accounts get an extra 5% on a single item, 35% in all, or 2 for the price of 1 · get verified 99.59% median purity across 281 lots 261 / 261 lots pass sterility
Black Friday sale
Offer2 for the price of 1 on compound vials and capsules
HowPut 2 of the same item and size in your cart and one is free, automatically. A single item is 30% off
ExcludesLab supplies and equipment · Ends Monday, November 30

2 for the price of 1 on compound vials and capsules — put 2 of the same item and size in your cart and one is free, automatically. A single item is 30% off.Solvents included. Lab supplies and equipment excluded · Ends Monday, November 30 · Laboratory use only

View catalogLaboratory use only

‹ Certificates BPC-157, TB-500 (Blend) Lot 1363

Lab report (Certificate of Analysis, COA)

BPC-157, TB-500 (Blend) · 11.7mg/11.56mg

Batch 1363 · tested September 5, 2025 (445 days ago) · released May 25, 2026 Discontinued variant

All tests passed

Batch
#1363 9 tests
Mass
11.7mg/11.56mg
Purity
>99.50%
Labs and accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01 · issuing labEagle Analytical · ISO/IEC 17025:2017 (A2LA) · sterility

1 unit tested for purity: >99.50% as printed

Conformity: Not assessable — every reported unit passed on all 6 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2025-09-05

Vanguard · issuing labEagle Analytical · sterility

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V250826-11 002

Lab reports for this batch

  1. Vanguard Laboratory this report · 9 tests · purity >99.50 (as printed) · tested September 5, 2025Vanguard · issuing labEagle Analytical · sterilityAll tests passed

Test by test

6 results on the report · 4 rows computed from the per-unit values · 2 labs · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓PurityWithin limits
>99.50 · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit printed (>99.50%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay) · BPC-157Within limits
10.94 mg · 1 unit · USP <621> (procedural chapter)
✓Net peptide content (assay) · TB-500Within limits
11.43 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between units · BPC-157Single measurement
1 unit printed (10.94 mg) · a between-unit spread needs two or more measured units
–Content consistency between units · TB-500Single measurement
1 unit printed (11.43 mg) · a between-unit spread needs two or more measured units
✓Heavy metalsWithin limits
all non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsWithin limits
<0.05 · 1 unit · USP <85> (procedural chapter) · limit <0.05 EU/mg (the lab's)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
–ConformityNot assessable
every reported unit passed on all 6 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2025-09-05 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Combined report · Batch 1363

One file holding the Vanguard Laboratory and Eagle Analytical Services reports for this batch, assembled by our quality team from the labs' files.

3 pages · Vanguard report V250826-11 002

Open PDF
Download

Tested by Vanguard Laboratory · Eagle Analytical Services Inc. · Released May 25, 2026

Permanent URL: https://peptidology.co/coa/bpc-157-tb-500-blend-lot-1363/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 16 times.