449 third-party lab reports published3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Tuesday night. For research use only.99.58% median purity across 254 lotsDefense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified242 / 242 lots pass sterility449 third-party lab reports published3 for the price of 2 on compound vials and capsules — put any 3 in your cart and the cheapest one is free, automatically. Solvents and lab supplies excluded. Ends Tuesday night. For research use only.99.58% median purity across 254 lotsDefense, VA, Federal and Public safety: your VerifyPass code adds 5% on top of 3 for the price of 2 · get verified242 / 242 lots pass sterility
Batch 1671 · tested March 23, 2026 (183 days ago) · released May 25, 2026
All tests passed
Batch
#1671 10 tests
Mass
10mg/3mg
Purity
99.34%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01
3 units tested for purity: 99.34 / 99.34 / 99.36% · spread 0.02 pt · net peptide content · tesamorelin 9.09 / 9.26 / 9.09 mg · net peptide content · ipamorelin 2.97 / 3.01 / 3.00 mg
Conformity: Conditional — every reported unit passed on all 7 test rows · purity spread 0.02 pt within the house limit · content spread (Tesamorelin) 1.9% within the house limit · content spread (Ipamorelin) 1.3% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-03-23
7 results on the report · 4 rows computed from the per-unit values · 2 labs · each test used up to 3 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows
✓PurityWithin limits
avg 99.35% · 3 units · USP <621> (procedural chapter)
✓Purity consistency between unitsWithin house limit
3 units: 99.34 / 99.34 / 99.36% · spread 0.02 pt · house limit · caution past 0.50 pt, outside past 1.00 pt · per-unit USP <621> results
✓Content consistency between units · TesamorelinWithin house limit
3 units: 9.09 / 9.26 / 9.09 mg · spread 0.17 mg, 1.9% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
✓Content consistency between units · IpamorelinWithin house limit
3 units: 2.97 / 3.01 / 3.00 mg · spread 0.04 mg, 1.3% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsPass
1 of 1 pass · 1 unit · USP <85> (procedural chapter) · limit <5.00 EU/mg (the lab's)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
!ConformityConditional
every reported unit passed on all 7 test rows · purity spread 0.02 pt within the house limit · content spread (Tesamorelin) 1.9% within the house limit · content spread (Ipamorelin) 1.3% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-03-23 · house check · agreement across all tests, unit to unit; QA approval corroborates
A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.