456 third-party lab reports published Volume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded 99.58% median purity across 258 lots 246 / 246 lots pass sterility

‹ Certificates GLOW Blend Lot 1363

Lab report (Certificate of Analysis, COA)

GLOW Blend · 10mg, 10mg, 75mg (95mg total)

Batch 1363 · tested August 28, 2025 (404 days ago) · released May 25, 2026 Discontinued variant

All tests passed

Batch
#1363 9 tests
Mass
10mg, 10mg, 75mg (95mg total)
Purity
>99.50%
Issuing lab accreditation
Vanguard · ISO 17025:2017 / A2LA #6377.01.01

1 unit tested for purity: >99.50% as printed

Conformity: Conditional — every reported unit passed on all 7 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-08-28

Vanguard · issuing lab

Verified by Vanguard Laboratory

This certificate is also hosted by Vanguard Laboratory — the issuing lab — on its own verification site.

View on VerifiedByVanguard.com
Laboratory ID V250820-9 001

Reports for this lot

  1. Vanguard Laboratory this report · tested August 28, 2025 · 7 results · QA approvalVanguard · issuing labAll tests passed

Test by test

7 results on the report · 5 rows computed from the per-unit values · 1 ISO 17025:2017-accredited lab · each test used up to 1 vial from this lot (rows are not added together) · every row names the chapter or house rule it follows

✓PurityWithin limits
>99.50 · 1 unit · USP <621> (procedural chapter)
–Purity consistency between unitsSingle measurement
1 unit printed (>99.50%) · a between-unit spread needs two or more measured units
✓Net peptide content (assay) · GHK-CuWithin limits
77.02 mg · 1 unit · USP <621> (procedural chapter)
✓Net peptide content (assay) · BPC-157Within limits
11.72 mg · 1 unit · USP <621> (procedural chapter)
✓Net peptide content (assay) · TB-500Within limits
10.66 mg · 1 unit · USP <621> (procedural chapter)
–Content consistency between units · GHK-CuSingle measurement
1 unit printed (77.02 mg) · a between-unit spread needs two or more measured units
–Content consistency between units · BPC-157Single measurement
1 unit printed (11.72 mg) · a between-unit spread needs two or more measured units
–Content consistency between units · TB-500Single measurement
1 unit printed (10.66 mg) · a between-unit spread needs two or more measured units
!Heavy metalsConditional
Cr: ND, As: 0.05, Cd: ND, Pb: 0.27, Hg: ND · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsWithin limits
<0.05 · 1 unit · USP <85> (procedural chapter) · limit <0.05 EU/mg (the lab's)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
!ConformityConditional
every reported unit passed on all 7 test rows · QA approval corroborates: Vanguard Laboratory, Tori Johnson, 2025-08-28 · house check · agreement across all tests, unit to unit; QA approval corroborates

A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.

Tested by Vanguard Laboratory · Released May 25, 2026

Permanent URL: https://peptidology.co/coa/glow-blend-lot-1363/

For research use only. Not intended for diagnostic or therapeutic use.

This certificate has been viewed 5 times.