493 third-party lab reports publishedVolume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded99.61% median purity across 283 lots263 / 263 lots pass sterility493 third-party lab reports publishedVolume pricing on every peptide, applied automatically in the cart: 3% off 2–3 · 8% off 4–5 · 12% off 6–7 · 15% off 8–9 · 20% off 10–19 · 25% off 20–29 · 30% off 30–39 · 35% off 40+ units · solvents and lab supplies excluded99.61% median purity across 283 lots263 / 263 lots pass sterility
2 units tested for purity, each printed >99.80% · net peptide content · ghk-cu 55.75 / 55.43 mg · net peptide content · bpc-157 10.29 / 10.28 mg · net peptide content · tb-500 10.87 / 10.83 mg
Conformity: Units agree — every reported unit passed on all 8 test rows · purity spread at most 0.20 pt within the house limit · content spread (GHK-Cu) 0.6% within the house limit · content spread (BPC-157) 0.1% within the house limit · content spread (TB-500) 0.4% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-03-10
8 results on the report · 5 rows computed from the per-unit values · 2 labs · each test used up to 2 vials from this lot (rows are not added together) · every row names the chapter or house rule it follows
✓PurityWithin limits
>99.80, >99.80 · 2 units · USP <621> (procedural chapter)
✓Purity consistency between unitsWithin house limit
2 units, each above 99.80% (the lab's reporting bound) · units differ by at most 0.20 pt · house limit · caution past 0.50 pt, outside past 1.00 pt · per-unit USP <621> results
✓Content consistency between units · GHK-CuWithin house limit
2 units: 55.75 / 55.43 mg · spread 0.32 mg, 0.6% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
✓Content consistency between units · BPC-157Within house limit
2 units: 10.29 / 10.28 mg · spread 0.01 mg, 0.1% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
✓Content consistency between units · TB-500Within house limit
2 units: 10.87 / 10.83 mg · spread 0.04 mg, 0.4% of the mean · house check · caution past 5%, outside past 10% · USP <905> is the compendial reference for between-unit uniformity (10 units; not claimable on 3)
✓Heavy metalsWithin limits
all non-detect · 1 unit · dose-scaled limits derived from USP <232> (limits chapter)
–Residual solventsNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–TFA residualNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓EndotoxinsWithin limits
45.20 EU/mg · 1 unit · USP <85> (procedural chapter)
–Container closureNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
–SolubilityNot on this lot's panel
not on this report · this batch was tested to our earlier standard; newer batches get all 15 tests
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (procedural chapter)
✓SterilityPass
1 of 1 pass · 1 unit · USP <71> (reference) · a rapid viability test used as an alternative to the USP <71> growth test; USP <1223> is the validation framework (informational chapter) · at Eagle Analytical
✓ConformityUnits agree
every reported unit passed on all 8 test rows · purity spread at most 0.20 pt within the house limit · content spread (GHK-Cu) 0.6% within the house limit · content spread (BPC-157) 0.1% within the house limit · content spread (TB-500) 0.4% within the house limit · QA approval corroborates: Vanguard Laboratory, Tori Johnson, Operations Manager, 2026-03-10 · house check · agreement across all tests, unit to unit; QA approval corroborates
A chapter number names the method or limit a result follows; it does not describe the product. Chapters below 1000 are procedures or limits; 1000-series chapters are informational. USP <905> is the compendial test for between-unit uniformity: it assays 10 units, so a 3-unit certificate cannot yield its acceptance value — the content row is a house check with <905> named as the reference only.
Combined report · Batch 1671
One file holding the Vanguard Laboratory and Eagle Analytical Services reports for this batch, assembled by our quality team from the labs' files.